Document extract

A cleaned text extract from the T1985 archive, shown for source transparency. This is one of the documents T1985 Intelligence draws on. Restricted, financial, and personal material is excluded from public view.

Architectural Dimensions & System Application Standard Building vs. Mansion Specifications Parameter Standard Building Luxury Mansion System Implications Floor-to-Ceiling Height 3.2m 4.2m Affects structural requirements and panel sizing Net Opening Length 2.0m 2.2m Determines panel width and configuration Typical Panel Width 1.0m 1.1m Influences weight and motorization requirements Typical Panel Height 3.0m 4.0m Critical for system selection and performance Glass Weight (Triple) ~75 kg/m² ~75 kg/m² Determines hardware and structural needs Total Panel Weight ~225 kg ~330 kg Key factor in system selection Dimensional Analysis & System Mapping !Dimensional Analysis Standard Building Configuration (3.2m height, 2.0m opening) `` ┌─────────────────────────────────────┐ │ │ │ │ │ │ │ │ │ │ │ │ 3.2m │ │ │ │ │ │ │ │ ├─────────────────┬───────────────────┤ │ │ │ │ Panel 1 │ Panel 2 │ │ 1.0m │ 1.0m │ │ │ │ └─────────────────┴───────────────────┘ ◄────────── 2.0m ─────────────► ` • System Recommendation: Venuro 3 Max • Configuration: 2-panel sliding system • Panel Dimensions: 1.0m width × 3.0m height • Weight Per Panel: ~225 kg (with triple glazing) • Motorization: Standard single-motor system • Track Configuration: 2-track system with removable threshold Luxury Mansion Configuration (4.2m height, 2.2m opening) ` ┌─────────────────────────────────────────┐ │ │ │ │ │ │ │ │ │ │ │ │ │ │ 4.2m │ │ │ │ │ │ │ │ │ │ ├──────────────────┬──────────────────────┤ │ │ │ │ Panel 1 │ Panel 2 │ │ 1.1m │ 1.1m │ │ │ │ └──────────────────┴──────────────────────┘ ◄─────────── 2.2m ──────────────► ` • System Recommendation: Venuro 4 • Configuration: 2-panel sliding system • Panel Dimensions: 1.1m width × 4.0m height • Weight Per Panel: ~330 kg (with triple glazing) • Motorization: Premium dual-motor system • Track Configuration: 2-track system with flush threshold Structural Integration Requirements !Structural Integration Header Detail Requirements Building Type Header Depth Support Material Load Capacity Standard Building 200mm Reinforced concrete 450 kg Luxury Mansion 250mm Reinforced concrete 660 kg Threshold Detail Requirements Building Type Threshold Type Recess Depth Drainage Standard Building Removable 45mm Integrated Luxury Mansion Flush 60mm Enhanced Side Jamb Requirements Building Type Jamb Width Anchor Points Thermal Break Standard Building 100mm 3 per side Required Luxury Mansion 120mm 4 per side Enhanced Installation Clearance Requirements !Installation Clearances Standard Building (Venuro 3 Max) ` ┌───────────────────────────────────────────────┐ │ │ │ ┌───────────────────────────────────────┐ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ └───────────────────────────────────────┘ │ │ │ └───────────────────────────────────────────────┘ ◄─── 50mm ───► ◄─── 50mm ───► ` • Top Clearance: 100mm minimum • Side Clearance: 50mm minimum each side • Bottom Recess: 45mm depth × full width • Structural Support: Continuous header beam Luxury Mansion (Venuro 4) ` ┌───────────────────────────────────────────────────┐ │ │ │ ┌───────────────────────────────────────────┐ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ └───────────────────────────────────────────┘ │ │ │ └───────────────────────────────────────────────────┘ ◄─── 60mm ───► ◄─── 60mm ───► `` • Top Clearance: 120mm minimum • Side Clearance: 60mm minimum each side • Bottom Recess: 60mm depth × full width • Structural Support: Reinforced header beam Motorization & Control Integration !Motorization Integration Standard Building System • Motor Location: Concealed in header • Power Requirements: 220V, 5A dedicated circuit • Control Integration: Smart home compatible • Emergency Operation: Manual override system • Maintenance Access: Removable cover panel Luxury Mansion System • Motor Location: Dual motors in header • Power Requirements: 220V, 8A dedicated circuit • Control Integration: Advanced BMS integration • Emergency Operation: Battery backup + manual override • Maintenance Access: Precision access panels
Continue in the guided assistant